Specifications at a Glance

Specifications at a Glance 2017-03-24T09:06:55+00:00

 

 

 

Gas Specifications

Model Framing Dimensions Viewing Area BTUs (NG) AFUE / P.4
(NG Efficiency)
Weight*
Hi Low
Abbot 20-1/4” H x 27” W x 15” D – Premiere
20-1/4” H x 27” W x 16-1/4” D – Deluxe
16” H x 25” W
26,000
10,500
68.3 %
115 lbs.
Newcomb
33-1/2” H x 38” W x 15-1/2” D
15” H x 32-1/2” W
21,000
13,000
65.1 %
115 lbs.
Palisade 32” H x 39-1/2” W x 10-7/8” D
15” H x 32-1/2” W
20,000
13,000
63.45%
105 lbs.
Austin 39” H x 70-1/2” W x 17 1/2” D
18-1/2” H x 62-3/4” W
38,000
27,000
69.10%
240 lbs.
Stanford 39” H x 58-1/2” W x 17-1/2” D
18-1/2” H x 52-3/4” W
36,000
21,250
68.75%
200 lbs.
Bennett 39” H x 44-1/4” W x 16-1/2” D
16-1/2” H x 42” W
30,000
22,000
69.5%
170 lbs.
Langley 32-1/2” H x 36” W x 8-3/4” D
12” H x 29-1/2” W
15,500
11,000
64.91%
90 lbs.
Bradley 32-1/2” H x 36” W x 15” D
16-1/2” H x 29” W
19,000
13,500
64.13%
110 lbs.
Thompson 37” H x 38” W x 15” D
16-1/2” H x 29” W
26,000
18,000
67.68%
125 lbs.
Tahoe 31” H x 47-1/4” W x 16” D
14-1/2” H x 39” W
40,500
29,000
Not applicable
outdoor model
110 lbs.

 

Model
Venting**
Ceiling /
Mantle Height
Abbot
3” flex vent on exhaust side
3” flex vent on the air intake side
Mantle Height = minimum 33” with a 4” deep mantle
Please see manual for other mantle clearances
Newcomb
4” flex vent on exhaust side
7” flex vent on the air intake side
Internal ceiling = minimum 48”
Mantle Height = minimum 40”
Palisade
4” flex vent on exhaust side
7” flex vent on the air intake side
Internal ceiling = minimum 40”
Mantle Height = minimum 40”
Austin
4” flex vent on exhaust side
7” flex vent on the air intake side
Internl ceiling = 58” from top of unit
Mantel height = 45”
Stanford
4” flex vent on exhaust side
7” flex vent on the air intake side
Internal ceiling = 58”
Mantle height = minimum 45”
Bennett
4” flex vent on exhaust side
7” flex vent on the air intake side
Internal ceiling = 58”
Mantle height = minimum 42”
Langley
3” flex vent on exhaust side
6” flex vent on the air intake side
Internal ceiling = 40”
Bradley
3” flex vent on exhaust side
5” flex vent on the air intake side
Internl ceiling= 40” from top of unit
Mantel height=42”
Thompson
4” flex vent on exhaust side
7” flex vent on the air intake side
Internl ceiling= 52” from top of unit
Mantel height=42”
Tahoe
No venting required
Internal ceiling = 48”
Mantle height = 42”

**Venting – Any certified 2 ply flex piping can be used. Certified on Duravent, Selkirk, Metal Fab, ICC



DISCLAIMER

Flames and flame colors on the website may appear differently in real life. To view the most accurate representation of the FIRE & ICE® flame and our regular flame sets, please visit your nearest dealer.


We reserve the right to update products, specifications and dimensions are subject to change. Please refer to the product manual to verify measurements and clearance requirements. All local building codes must be followed.